Quick read
Usually it's a Sunday night. Heating's been on since lunchtime, somebody walks past the boiler cupboard and the needle on the gauge is past 2.5 bar and leaning on the red bit at 3. Boiler pressure too high looks a lot more alarming than it normally is, though it won't sort itself out either.
On a sealed system, so any combi and most system boilers, the ones with a gauge on or under the boiler, you're wanting roughly 1 to 1.5 bar with everything cold. Water expands as it heats, and the reading goes up with it to somewhere around 1.5 to 2 bar once the heating's been running. Half a bar or so of a rise is just the boiler doing its job, your manual has the exact numbers for your model. A jump of more than 1 bar from cold to hot isn't normal. Neither is a gauge that's already high first thing in the morning before the timer's even brought the heating on.
Check the filling loop first
Topped up the pressure in the last week or so? Then look here before anything else.
The filling loop is the silver braided hose under the boiler, or on some a short bit of pipe with a valve or two on it, and it joins the heating to the cold mains. Leave one of those valves a crack open and mains water keeps trickling in for as long as it's left, and the pressure goes up and up with it. Lever or screwdriver slot sitting across the pipe means it's shut, along the pipe means it's open. Close it gently and don't force a valve that won't turn. A few boilers have the filling key built into the underside and it looks nothing like a hose at all, if you can't tell which valve is which leave it alone.
Why boiler pressure keeps rising with the heating off, or only when it's on
The gauge only tells you the pressure's high. It can't tell you why, and two faults that have nothing to do with each other end up showing the exact same number on it. What splits them is when the needle moves.
Say the filling loop is definitely shut, the heating's off, the house is cold, and over a day or two the needle still creeps up. That's mains water getting into the heating from somewhere. Most often it's the filling loop valve itself letting by, turned off as far as it goes and still passing a dribble because the washer inside is done. On a combi there's another possibility and it's a bigger job. The plate heat exchanger is the part that heats your hot taps using the heating water, mains water on one side of a thin steel plate and heating water on the other, and when that plate pinholes the mains side is at the higher pressure so it pushes through into the heating circuit. Nothing drips anywhere. You'd never know except for the gauge. Both of those are for an engineer, the heat exchanger especially since it's inside the boiler.
The other pattern is the commoner one by a distance. Gauge reads a perfectly normal 1.2 cold. Boiler pressure rises when the heating is on, quickly, inside half an hour it's at 2.8 and the boiler's locked out or the pipe outside is dripping. Then overnight it cools, drops to 0.6, somebody tops it up in the morning and round it goes again. That's the expansion vessel. It's a flat round tank, inside the casing on most combis, with a rubber diaphragm across the middle, air on one side and heating water on the other, and the air is a cushion for the water to push into as it expands. Lose the air charge or split the diaphragm and the cushion's gone. The water has nowhere to go so the pressure shoots up, the pressure relief valve opens at about 3 bar and lets water out down the copper pipe through the wall, and now there's less water in the system so it reads low cold. Worcester Bosch reckon anything over a 1 bar rise between cold and hot means the vessel wants looking at. And a relief valve that's lifted a few times often won't reseat properly afterwards, it just keeps weeping down the wall.
Which is why this one so often gets reported as the opposite fault. A boiler that keeps losing pressure is sometimes a high pressure boiler that's been dumping water outside every afternoon, why a boiler keeps losing pressure has that side of it. On an Ideal the low end shows up as an F1 lockout, and on a Vaillant the swings can turn into an F.75 that keeps coming back. Water on the floor as well as down the wall outside is a different problem again, see boiler leaking water and deal with that first.
Don't go at the expansion vessel with a bike pump. People do. The charge has to be set with the heating side drained right down, and a split diaphragm lets the air straight back out anyway.
How to reduce boiler pressure if you overfilled it
Got a bit keen at the filling loop and it's sitting at 2.5 cold? That one's yours to sort, with a radiator key.
Turn the heating off at the boiler or the programmer and give the radiators time to go properly COLD, an hour or two, because what comes out a bleed valve on a hot radiator is hot enough to scald and it comes out at a fair rate with the pressure up. Check the filling loop's shut while you're waiting. Then pick a radiator you can easily get a bowl under, wrap a cloth round the bleed valve at the top corner, hold the bowl underneath and open it with the key a quarter turn, no more. Maybe a hiss of air first and then water. Let a wee bit out, close it, go and look at the gauge, it drops quicker than you'd expect. Small goes like that until it reads 1 to 1.5 bar cold and then stop, that's how to lower boiler pressure without making a second problem.
If it's back up by the next day, stop bleeding it. Draining and refilling over and over waters down the inhibitor your installer put in to stop the radiators rusting from the inside, and every top up brings in fresh mains water with oxygen in it. It's a fault, go back up a section.
NEVER open the pressure relief valve by hand to let the pressure off. There's a little lever or a red cap on it and it looks like the obvious way, but it's a safety valve and once it's been opened it often won't seal again. Then it drips down that outside pipe for good and there's another part on the repair.
Getting high boiler pressure sorted in Edinburgh
Boiler still under the manufacturer's warranty, phone them before anybody else touches it. Whatever it turns out to be the casing stays on, it's Gas Safe work behind there.
Otherwise we do boiler repair from Danderhall across Edinburgh, Dalkeith and the Lothians. Before you ring 0131 644 0045 jot down what the gauge reads cold, what it gets to hot and whether it climbs with the heating off, or put the same in the repair request form. How a callout goes is on the boiler repairs page.
High boiler pressure questions
What people ask us once the needle's gone into the red.
With the heating on, usually not. Cold, it's on the high side for most, so check your manual.