Boiler Leaking Water? What to Do and Where It's Coming From
Boilers
2026-11-26

Boiler Leaking Water? What to Do and Where It's Coming From

Boiler leaking water from the bottom or the pipe outside? What to do before an engineer gets there, and how to tell which leak you've actually got.

SM
Macara Heating Team6 minute read

Quick read

Take a photo of the wet patch and the gauge before you start mopping, it says more than a description over the phone.
A weep that dries as fast as it comes out leaves a white or greenish crust on the fitting, so look even if the floor's dry.
Turning the stopcock off leaves you without cold taps too, fill the kettle and a few bottles first if the leak gives you a minute

Most people find it the same way, a wet patch on the lino under the kitchen units or a drip landing on the shelf of pans in the cupboard, and the first thing they reach for is a towel. Leave the towel a minute. A boiler leaking water has mains electricity a few inches from the drip and that gets dealt with before the floor does.

Boiler leaking water? What to do first

Smell gas as well and stop there. Open the doors and windows if you can do it safely, nothing with a naked flame, don't flick any switches on or off, and phone the National Gas Emergency Service on 0800 111 999.

No gas smell, then it's the power. Somewhere near the boiler there'll be a fused spur or an isolation switch on the wall, often a wee white plate with a red light in it. Switch the boiler off there if the switch is dry and your hands are dry. If water's been running down over it or there's a plug sat in a puddle don't go near it, go to the fuse box (the consumer unit) and turn it off there if you can get to it safely.

Then the water. A washing-up bowl or a baking tray under the drip, towels round it, and get anything you care about out of that cupboard. In a flat chap the door downstairs or text them, because it can be through their ceiling before there's a puddle worth mentioning on yours.

Pouring out, and coming off the cold mains pipe into the boiler or a pipe next to it? Turn the stopcock off. Under the kitchen sink is the usual place but plenty of older Edinburgh flats have it in a hall cupboard or under a floorboard, and nobody ever knows which until they're on their knees with a torch.

Don't top the pressure up to keep it going either. Every drop you put in at the filling loop has to come out somewhere and it comes out at the leak.

And it'll keep dripping after it's off. People phone us thinking the switch hasn't worked, but the heating system is still full of water and still under pressure, so it can carry on for a good while yet. Keep emptying the bowl.

Where is the water coming from? Underneath, the pipe outside or inside the casing

Get a torch and look, from the outside of the boiler only. The front casing stays on. There's gas, live electrics and parts hot enough to burn you behind that panel and none of it is a job for anyone who isn't Gas Safe registered.

Start underneath because that's where the water usually is, a boiler leaking from the bottom is mostly a fitting rather than the boiler itself. A combi boiler has five or six pipes coming down out of it and most have compression joints and a wee isolation valve on them, the sort with a slot for a flat screwdriver. Any of those can start to weep, more so if somebody's been working nearby fitting a new sink and leant on a pipe. Run a dry tissue along each one, it shows wet straight away where a finger won't. Don't put a spanner on anything. Overtightening a compression joint can turn a slow weep into a proper leak and then you're wanting the stopcock after all. (Half the boilers in Edinburgh flats seem to live in the hall press with the hoover and the ironing board, and nobody notices a thing until the ironing board cover's soaking.)

The filling loop's down there too, a silver braided hose with a tap at each end or a lever built into the underside on some combis, the thing you top the pressure up with. If one of its valves wasn't shut right off the last time somebody used it, it can weep at the joint and it can also keep feeding water in, so the pressure creeps up and up. Check both are fully closed, that's about the only thing under there you should be turning.

Creeping pressure ends up outside. Through the wall behind or below the boiler there's a short copper pipe, usually turned down at the ground, and that's the outlet from the pressure relief valve. It should be dry. A drip off the end or a wet streak down the render under it means the valve's been letting water go, nearly always because the pressure got too high, and a relief valve that's lifted a few times doesn't always seat properly again. Why the pressure goes up in the first place is in our guide to boiler pressure too high. DON'T go opening the valve or twisting the cap on it to see what happens.

The other pipe outside is plastic, white or grey and a bit fatter, and it's a different thing entirely. A condensing boiler makes water as it burns and the condensate pipe carries it off to a drain or a soakaway. Joints on it pull apart, the plastic cracks, and in a cold snap the outside run freezes solid so the condensate backs up and spills out of the trap or a joint back indoors, usually with the boiler stopped on a fault code by then as well. It's mildly acidic so wipe it up, don't leave it soaking into the cupboard base. Been freezing overnight? Read the frozen condensate pipe guide.

Water you can see coming from inside the case itself, running down the inside of the front panel or dripping out the gap along the bottom, is an internal part and there's no checking it yourself. We'd be looking at the pump seal first on an older boiler, or the diverter valve on a combi (the bit that switches it between heating and hot water). An automatic air vent stuck open will spit water too. A heat exchanger that's corroded through is the one nobody wants. Whatever it turns out to be it's sat right beside the PCB and the gas valve, so the power stays off and the cover stays on until a Gas Safe engineer gets there.

What the pressure gauge tells you

Needle or digits, whichever your boiler has, read it before you do any more mopping. Somewhere around 1 to 1.5 bar cold is where most of them sit but your manual has the figure for your model.

Up near 3 bar and it's probably the relief valve that's dripping outside, often down to an expansion vessel that's lost its air charge so the hot water has nowhere to expand into. Falling, or right down to 0, means water's leaving faster than anyone's putting it back, the leak you've found or one you haven't yet, and why a boiler keeps losing pressure goes through it. On an Ideal that often shows up as F1, there's an Ideal F1 guide for that one. Steady with water still on the floor points away from the heating side altogether, back at the condensate or the cold mains.

Can you keep using a leaking boiler?

Water from inside the casing, NO, leave it off. A slow weep on a joint underneath and nowhere near the electrics you can probably limp on with a bowl under it for a day or two, it won't fix itself though. Still under the manufacturer's warranty? Check the terms before you pay anybody for a repair.

Getting a leaking boiler repaired in Edinburgh

We're based in Danderhall, Gas Safe registered, and do boiler repair across Edinburgh, Dalkeith and the Lothians. Phone 0131 644 0045 and tell us roughly where the water was and what the gauge said, or send it through the repair form. How a callout works is on the boiler repairs page.

Common Questions

Leaking boiler questions

The ones we hear most from folk who've just found water under the boiler.

Water and mains electrics in the one box, so treat it as dangerous till somebody's looked.