F.28 is ignition failure on a Vaillant, the boiler went to light at start-up and never saw a flame. On an ecoTEC plus it has three goes at it before giving up and locking itself out, and then it sits there cold until somebody clears it. Vaillant write it F.28 with the dot and most folk search it as F28, same thing.
Smell gas anywhere in the house and the boiler can wait. Windows open, turn the meter off at the handle if it's safe to get to, don't touch a light switch or anything with a flame and phone the National Gas Emergency Service on 0800 111 999.
Frozen condensate pipe and F28 in cold weather
Plenty of the F.28 calls we get in a cold snap have nothing to do with gas at all. An ecoTEC is a condensing boiler and it makes water as it burns, a fair amount of it, which drains away through a white or grey plastic pipe that usually goes out through the wall and down to a gully. When that pipe freezes the water backs up into the boiler and fills the condensate trap, and Vaillant list that as one of the causes of F.28. You'll often hear it first. A gurgle like a sink that won't drain, sometimes for a good while before the code comes up (and it's always worst about 6am when the heating kicks in after the coldest bit of the night, which is exactly when nobody wants to be out the back in their slippers).
The bad ones are the long runs. Pipe comes out the back wall and trails along the harl for a couple of metres in the thin 21.5mm stuff before it drops into a drain at the far corner, north side of the house where the sun never gets near it. It freezes at the bend or right at the open end over the gully, and you can sometimes see a wee plug of ice sitting in the mouth of it.
If you can get at the frozen bit with both feet on the ground, pour warm water over it from a jug or a watering can, or hold a hot water bottle or a warm cloth on it for a few minutes. NEVER boiling water, it can crack the plastic and you'd be lucky not to scald yourself. No ladders either, a pipe coming out the wall upstairs is a job for us. Once it's running again give the boiler one reset. The frozen condensate pipe guide has the full method.
Mild out and the pipe's clear? Then the blockage could be the condensate trap inside the boiler, and that's an engineer with the casing off.
Is the gas supply getting to the boiler?
Turn a ring on the hob first. If that won't light either the Vaillant is probably innocent and it's the supply.
Prepayment meters catch a lot of people about now because the boiler is suddenly getting through credit it wasn't touching in September, and once the emergency credit's gone the gas just stops. Top it up and make sure the meter or the in-home display actually shows credit on it. Out at the newer estates round Dalkeith and Shawfair the meter tends to be in a box on the outside wall, in an older flat in town it could be under the stairs or in a press in the hall. Credit on, the handle on the meter lying in line with the pipe, and still nothing gas-fired works? That's your gas supplier to phone.
Hob lights fine, then crouch down and look under the boiler. There'll be a few pipes coming down and the gas one usually has a yellow handle on it, the isolation valve. Look at it, DON'T turn it. If it's sitting across the pipe and you don't know who shut it or why leave it, it may have been isolated for a reason and somebody needs to find out what before it gets opened up again.
Resetting a Vaillant F.28 fault
On the ecoTEC plus it's the reset button, the fault clearance button in some of the manuals, held in for about a second. Other models vary so check the booklet. Vaillant say up to three tries, we'd say ONE, and if F.28 comes straight back stop pressing it and phone a Gas Safe engineer.
What fails inside a Vaillant ecoTEC
Past the gas and the condensate it's inside the case, and the casing stays on. There's gas and live mains behind that panel, whether it's an ecoTEC plus or an ecoTEC pro combi squeezed into a kitchen cupboard, and it's Gas Safe work.
Ignition electrode is where we'd start. It sits right at the burner and takes a battering, the tip wears down or the ceramic cracks, and the lead going to it can break down until the spark is jumping somewhere it shouldn't. After that it's the working gas pressure measured at the gas valve while the boiler is actually trying to light, which is a reading you can't get any other way, and whether the valve is opening at all. A blocked air intake or a flue that's been knocked out of line will upset the burner too. The PCB gets blamed a lot. It comes last on our list because it's the dearest guess to get wrong.
F.28 vs F.29, F.75 and the pressure gauge
F.29 is close enough that people mix them up on the phone. That one's flame lost once it's already running, it lit, burned away for a bit, dropped out and couldn't relight, where F.28 never got going in the first place. An F29 can come down to the gas supply as well so the hob and meter checks still count.
F.75 is a water pressure fault and nothing to do with lighting, there's a separate Vaillant F75 guide for it. Glance at the gauge anyway. About 1 to 1.5 bar with the system cold is normal on a Vaillant and low pressure usually brings up its own code, not F.28, but if it's low or keeps falling have a read of why a boiler keeps losing pressure.
Vaillant warranty or local boiler repair?
Find the warranty paperwork or the registration email before you ring anybody, inside warranty Vaillant want to hear from you first. They can charge for the callout if what they find isn't the boiler's fault though, a frozen condensate pipe or a prepay meter sat on zero, so the ten minutes outside with a jug is worth it.
Out of warranty or you'd rather have someone local, we're Gas Safe registered and do boiler repair across Edinburgh, Dalkeith and the Lothians. Ring 0131 644 0045 with the model off the front of the boiler, the code and whether it was clicking before it locked out, or put it through the repair request form. How we handle a callout is on the boiler repairs page.
Vaillant F28 questions
What folk ask us when the Vaillant locks out on F.28.
Ignition failure. It tried lighting at start-up, never saw a flame and locked out.